S52i Weigh Belt & Belt Scale Integrator

THAYER’s S52i is a compact, cost effective belt scale integrator. Advanced microprocessor based technology is used to process both weight and speed signals and output accurate and stable reading of flow rate and totalize weight of bulk solid materials. The S52i integrator is compatible all THAYER non-commercial Belt Scales and Weigh belt scales. As a retrofit, the unit will work with any single or dual load cell based weigh-bridge.

  • Conveyor Belt Scale Integrator
  • Weigh Belt Integrator
  • Strain Gauge and LVDT Load Cells
Category:

Description

S52i Weigh Belt or Conveyor Belt Integrator

THAYER’s S52i Integrator is a full featured instrument in a single, compact package. It performs the same functions as an instrument costing many times more without sacrificing the accuracy associated with THAYER products. Simplicity of use has always been a very important factor in designing an instrument and the S52i has inherited all the time and labor saving methods THAYER has developed over the years.

The S52i Instrument can be used on most belt conveyor weigh belt systems to provide continuous information about the flow of material to its process by monitoring the load and speed. The weigh system must use a strain gauge to sense weight; however a variety of sensors can be used to sense the speed. Weight information is processed as weight per length and speed is processed as unit length per time. Integrated together, a great deal of information is available about the system, such as: flow rate; accumulated weight (total); belt loading; belt speed; etc.

Closed-loop control

Weigh Belt Feeder Using S52c Controller | Belt Scale Integrator | Tech Weigh Belt Scales

Input Power Requirements

– Voltage Range: 120 to 240 VAC
– Frequency Range: 50 to 60 Hertz
– Phase Requirement: Single Phase
– Power Consumption: < 43 W
– Supply Protection: Fused

Environmental Requirements

– Area Classification: Non-Hazardous
– Operating Temperature: 14 to 149° F (-10° to +65° C)
– Operating Humidity: 10 to 90% Non-Condensing
– Storage Temperature: -4 to 185° F (-20° to +85° C)
– Storage Humidity: 5 to 95% Non-Condensing
– Altitude: Operational Up to 2000 Meters
– Altitude Storage Up to: 3000 Meters (70 kPa)
– Cooling Method: Natural Convection
– Pollution Degree: 2

Standard Dimensional Requirements

– Open Chassis: Type IP23, 8.0″ H x 6.0″ W x 4.5″ D
(203.2 x 152.4 x 114.3 mm)
– Enclosed: Type IP66, 11.81″ H x 9.84″ W x 5.91″ D
(300 x 250 x 150 mm)

Agency Approvals
– Underwriters Laboratories, UL File #E208487

Standard Input/Output Specifications

– Analog Input: 2-wire Loop powered
Range: 4-20 mA typical (30mA max.)
Input Impedance: 169 Ohm
Voltage drop: 3.38V typical (5.1 max.)
Resolution: 22 bit
AI-1 Programmable, Field Selectable
– Analog Output: Isolated 4-20 mA into
750 Ohm Load Maximum
Sourcing, +24VDC Compliance Voltage, Range 0-24 mA Resolution 16 bit
AO-1 Programmable, Field Selectable
– Digital Inputs: Require Dry Contact Closures
Sourcing, +12VDC with 10 mA Minimum Sink Current
DI-DS Discrete – Drive Status
DI-1, 2, 3 Programmable, Field Selectable
– Digital Outputs: Isolated Relay Outputs
DO-1, 2 Form A, 140 VAC/ 200VDC @ 0.05A,
14 VAC/20 VDC @ 0.5A,
Contact Rating 10W, Resistive load
Programmable, Field Selectable
DO-3 Form A, Solid State Relay, 240 VAC/VDC, 100 mA maximum.
Programmable, Field Selectable
Remote Totals Form A, Solid State Relay, 240 VAC/VDC, 100 mA maximum.