Thayer Scale
Email: Mail@ThayerScale.com
(781) 826-8101
(781) 826-7944 FAX


As recently seen in
Powder Bulk Solids

Special Aspects of
Light-Density Material Weighing


Biomass Energy Applications
    
 

Model S52i Integrator

THAYER’s S52i Integrator is a full featured instrument in a single, compact package. It performs the same functions as an instrument costing many times more without sacrificing the accuracy associated with THAYER products. Simplicity of use has always been a very important factor in designing an instrument and the S52i has inherited all the time and labor saving methods THAYER has developed over the years.

The S52i Instrument can be used on most belt conveyor weigh belt systems to provide continuous information about the flow of material to its process by monitoring the load and speed. The weigh system must use a strain gauge to sense weight; however a variety of sensors can be used to sense the speed. Weight information is processed as weight per length and speed is processed as unit length per time. Integrated together, a great deal of information is available about the system, such as: flow rate; accumulated weight (total); belt loading; belt speed; etc.


Input Power Requirements
  • Voltage Range:
  • Frequency Range:
  • Phase Requirement:
  • Power Consumption:
  • Supply Protection:
120 to 240 VAC
50 to 60 Hertz
Single Phase
< 43 W
Fused
   
Environmental Requirements
  • Area Classification:
  • Operating Temperature:
  • Operating Humidity:
  • Storage Temperature:
  • Storage Humidity:
  • Altitude:
  • Altitude Storage:
  • Cooling Method:
Non-Hazardous.
14 to 158° F (-10° to +70° C).
10 to 90% Non-Condensing
-4 to 185° F (-20° to +85° C).
5 to 95% Non-Condensing.
Operational Up to 2000 Meters
Up to 3000 Meters (70 kPa)
Natural Convection
    
Standard Dimensional Requirements
  • Open Chassis, Type IP23 8.0”H x 6.0”W x 4.5”D(203.2 x101.6 x 114.3 mm)
  • Enclosed, Type IP66 11.81”H x 9.84”W x 5.91”D(300 x 250 x 150 mm)
    
Standard Input/Output Specifications
  • Analog Output: Isolated 4-20 mA into 750 Ohm Load Maximum Sourcing,  +24VDC
    Compliance Voltage, Range 0-24 mA AO-1 Programmable, Field Selectable
  • Digital Inputs: Require Dry Contact Closures Sourcing, +12VDC with 10 mA Minimum
    Sink Current
    DI-DS Discrete - Drive Status
    DI-1, 2, 3 Programmable, Field Selectable
  • Digital Outputs: Isolated Relay Outputs
    Max. Voltage 240 VAC/VDC, Max. Current 120 mA
    DO-1,2,3 Programmable (Form A) , Field Selectable Rem.
    Totals Discrete – Remote
    Totalizer (Form A)
    
Communication Options:
  • DeviceNet,
  • PROFIBUS,
  • Ethernet/IP & MODBUS/TCP,
  • Q2 – Allen-Bradley DF1 and MODBUS RTU.

Products: Loss-In-Weight Feeders | Instrumentation | Volumetric Feeders | Weigh Belt Feeders | Conveyor Belt Scales | Material Flow Aids